Installinig Notice of The Electric Heating Belt

- Apr 20, 2020-

1, when the installation of the electric heating belt, should not be hard folding or long distance pull trample. Take care to prevent damage to the outer insulation of the electric heating belt.
2. When connecting the electric heating belt, it should be noted that the maximum usable length of the electric heating belt should not exceed, and the maximum usable length of the electric heating belt should be 100 meters.
3. Conventional gate and flange shall be constructed according to the legend of the manufacturer's "guide to design, installation and maintenance".
4. The position of the flat power pack should be close to the wall of the pipe at the lower end of the pipe level.
5. Construction is carried out according to the installation coefficient
6. The electric heating belt shall be pasted longitudinally with aluminum foil tape throughout the whole process. Every interval of 500mm-700mm shall be wrapped with heat-resistant tape for one week in the radial direction and fixed.
· at the power supply and the tail end, 1 meter should be reserved for the electric strip, and 0.5 meter should be reserved for the two-way and three-way junction boxes, which should be fixed on the pipeline
8. It is strictly prohibited to mix the power cord with the electric belt whose temperature is lower than the highest surface temperature of the electric belt.
9. If the hot body is a non-metal body, apply the aluminum foil tape to increase the contact area.
10. It is strictly prohibited to tie the wire to the electric tropics.
11. The medium at the flange is leaked. When winding the electric heating belt, avoid its direct underneath.
12. Connect the power supply at one end of the cable and the wiring core at the other end. And cut to "V" type, must use the matching head to seal tightly, the use of shield layer of the electrical terminal must be separated from the shield layer 10 cm, to prevent short circuit. On explosion-proof occasions, silicone rubber seal should be applied after wiring.
13. Install a hot spot and measure the primary insulation. The shielding layer must be grounded and the insulation resistance value is 220 m.
14. The construction of insulation layer shall be carried out after the installation of the electric heating belt and the acceptance inspection.1, when the installation of the electric heating belt, should not be hard folding or long distance pull trample. Take care to prevent damage to the outer insulation of the electrical heating belt.
2. When connecting the electric tropics, it should be noted that the maximum usable length of the electric heating belt should not exceed, and the maximum usable length of the electric heating belt should be 100 meters.
3. Conventional gate and flange shall be constructed according to the legend of the manufacturer's "guide to design, installation and maintenance".
4. The position of the flat power pack should be close to the wall of the pipe at the lower end of the pipe level.
5. Construction is carried out according to the installation coefficient
6. The electric heating belt shall be pasted longitudinally with aluminum foil tape throughout the whole process. Every interval of 500mm-700mm shall be wrapped with heat-resistant tape for one week in the radial direction and fixed.
· at the power supply and the tail end, 1 meter should be reserved for the electric strip, and 0.5 meter should be reserved for the two-way and three-way junction boxes, which should be fixed on the pipeline
8. It is strictly prohibited to mix the power cord with the electric heating belt whose temperature is lower than the highest surface temperature of the electric belt.
9. If the hot body is a non-metal body, apply the aluminum foil tape to increase the contact area.
10. It is strictly prohibited to tie the wire to the electric heating belt.
11. The medium at the flange is leaked. When winding the electric heating belt, avoid its direct underneath.
12. Connect the power supply at one end of the cable and the wiring core at the other end. And cut to "V" type, must use the matching head to seal tightly, the use of shield layer of the electrical terminal must be separated from the shield layer 10 cm, to prevent short circuit. On explosion-proof occasions, silicone rubber seal should be applied after wiring.
13. Install a hot spot and measure the primary insulation. The shielding layer must be grounded and the insulation resistance value is 220 m.
14. The construction of insulation layer shall be carried out after the installation of the electric heating belt and the acceptance.