How to installing capillary thermostats?
1. The user must put forward the order model and specifications according to the characteristics of their products and the temperature to be controlled.
2. When the temperature controller is installed, the temperature sensing tube should be as close as possible to the temperature-controlled surface to achieve accurate temperature control.
3. Do not deform the temperature sensing tube during installation, so as not to affect its performance.
4. Do not allow conductive gases or conductive substances to enter the thermostat or contaminate the surface of the thermostat to avoid affecting the electrical insulation performance.
5. The M4 wire of the mounting bracket should not be too long, otherwise the performance of the thermostat will be damaged.
6. The switch box is a ceramic part of electrical appliances, so handle it with care to avoid damage.
7. The bending radius of the capillary tube cannot be less than 5mm.

How to order hot capillary thermostats?
1. The size of the shaft and its initial rotation angle need to be set according to the needs of the customer.
2. The disconnection temperature and characteristic curve of hot capillary thermostats shall be determined according to the customer's finished product and temperature control matching test.
3. There are various terminal sizes and directions, and the length of capillary tube and sheath tube can be selected by customers.
4. In order to facilitate the customer to install the thermostat, the hot capillary thermostats can also be welded with different diameters of temperature sensors.