How to determine the power of the dry-burning electric heater?
The dry-burning electric heater includes a mold electric heating tube and an air electric heating tube. The power design of the dry-burning electric heating tube is a key factor in determining the service life of the electric heater. Therefore, how to determine the power of the dry-burning electric heater is a big question. Today, I will introduce to you what is the power of the dry-burning electric heating tube based on?

The power of the dry-burning electric heater is determined according to the ratio of the length of the electric heating tube to the power, that is, the power per meter. The so-called power per meter refers to the power that can be designed in one meter of heating area.
The dry-burning electric heater has air circulation. It is recommended that the ratio between the length (m) of the heating area and the power (KW) is: 1:1.5; that is, 1.5KW power is used for the heating area of 1 meter; the dry-burning electric heating tube has no air circulation. It is recommended that the proportional relationship between the length (m) of the heating area and the power (KW) is: 1:1; that is, the heating area of 1 meter is used for 1KW power;