Mounting Guidelines for Ruby Color Halogen Infrared Quartz Heater in Shoe Machines:
Mounting Position:
Install the heater 10-20cm above the target area (shoe material)
Ensure parallel alignment with the work surface for even heat distribution
Position to cover the entire treatment area without obstructions
Mounting Hardware:
Use high-temperature resistant brackets (stainless steel recommended)
Secure with heat-resistant screws or clamps (M4-M6 size typically used)
Include vibration dampeners if machine operates at high speeds
Electrical Connections:
Connect to a dedicated circuit matching the heater's voltage rating (typically 220V/50Hz or 110V/60Hz)
Install a properly rated thermal cutoff switch (usually 120-150°C)
Include a ceramic terminal block for secure wiring
Safety Considerations:
Maintain minimum 5cm clearance from flammable materials
Install a protective mesh guard if workers access the area
Ensure proper grounding (ground resistance <4Ω)
Performance Optimization:
Angle the heater at 15-30° for focused applications
Use reflectors to direct infrared energy efficiently
Allow 5-10 minutes warm-up time before production
Maintenance Access:
Design mounting for easy bulb replacement (typically needed every 3000-5000 hours)
Allow space for periodic cleaning of quartz tubes
Ensure access to connection points for maintenance